HVAC contractor resource















  Nominal Capacities
  55 to 112 Mbh output

  Efficiency
  94% AFUE

  Warranty
  Heat Assembly - Lifetime
  Other Parts - 5 Years


Consumer Brochure
PDF FILE



  



 
Diamond® ULTRA Series High Efficiency (PXU-V)
The York Diamond® ULTRA high-efficiency gas furnace eliminates the trade-off of economy for dependable, reliable performance. Or, the choice between quiet operation and even, whole-house heating. At 94% and 80% AFUE, a new York Diamond ULTRA gas furnace allows customers to slash operating costs as much as 60%, while keeping operating sounds to a mere whisper. These furnaces circulate more air throughout the home for longer periods of time, reducing stratification from room-to-room and floor-to-floor. Longer run cycles can improve air quality by improving air filtration. The secret is York two-stage, variable-speed furnace engineering. It’s a York engineering achievement providing unparalleled home comfort and operational economy.
 
Special Benefits
  • Two-stage heating operation includes: two-stage gas valve, two-speed inducer operation, and variable-speed blower operation.
  • Install it as two-pipe (sealed combustion) or single-pipe vent (using indoor combustion air).
  • Top intake and vent connection allows installation in narrow locations.
  • Insulated blower compartment.
  • No special vent termination kit required.
  • Full-height blower compartment allows side- return application with no return air box.
  • Field selectable continuous fan speed.
  • Low unit amp requirement for easy replacement application.
  • Ignition control supports 24 or 120 volt circuit outputs.
  • 24V, 40VA control transformer and blower relay supplied for add-on cooling.
  • Hi-tech tubular aluminized steel primary heat exchanger.
  • Secondary (condensing) heat exchanger of 29-4C high-grade stainless steel.
  • Variable-speed blower motor with 12 cooling CFM selections.
  • Electronic hot surface ignition saves fuel costs, increases dependability and reliability.
  • Two-speed induced combustion system with Inshot main burners for quiet, efficient operation.
  • Adjustable 10-, 15-, 20-minute delay timer allows two-stage operation with single-stage thermostat.
  • Timed-on, adjustable-off blower capability for maximum comfort.
  • Blower-off delay for cooling SEER improvement.
  • Built-in, high-level self-diagnostics with fault code display.
  • 100% shut-off main gas valve and blower door safety switch for extra security.
York heating and cooling products



Powered by Contractor Websites, Inc.

The Building Trades Internet Connection
ConWebs.com
©Copyright